Multi-Voltage Loop Detector

Multi-Voltage Loop Detector florida
Request for free site survey
Part No : iW-SP-MLD
Application:

Specially designed the MVP D-TEK for application where vehicle detection is needed. MVP D-TEK makes it simple to detect vehicle at traffic lane for Arming Identification Device like Active RFID Reader or iParkControl Metal Ticket Dispenser and Automatic Closing and Opening of iParkBarrier.

It solves the problem of not knowing which voltage to take for service call or an installation. Reduce the cost of inventory by stocking only one Universal Voltage Loop Detector.

The loop buried in a rectangular (2’X4’ or 4’X6’) shape in the pavement has proven to be the most reliable vehicle sensor in the market today. It is connected to a self tuning, digital vehicle detector that can sense the changing inductance in the loop and identify when the vehicle comes upon the loop and also when the vehicle leaves the loop.

Both these signals are critical to the logic used in controlling the position of the gate in different lane configurations. The detector is powered by a 24V power and comes with a harness to connect all the other signals in the universal Logic Box in the barrier gate.

Up to two such detectors can be housed in the logic box to handle the most common “Free Out”.
access control systems florida

Universal

Universal Voltage: Covers All The Voltages.

door access control systems florida

Mode

Operates In Both Fail Safe And Fail Secure Modes.

biometric access control systems florida

Enhancement

Enhanced Lightning/Surge Immunity.

fingerprint access control florida

Housing

Aluminum RF Shield Housing.

access control device florida

Conditioner

Built-In Loop Conditioner.

access control products miami

Isolation

Loop Isolation Transformer.

biometric systems florida

Diagnostics

Loop Diagnostics.

video surveillance systems florida

Contacts

Gold Plated Control Contacts.

cctv security florida

Relay

2 Relays (Presence & Pulse or Presence).

security cameras florida

Economical

Reduced Inventory Costs.

Power Supply: 9VDC to 240VAC

Current Consumption:

19.2mA @ 9VDC, 18.8@ 12VAC/DC, 17.3mA @ 24VAC, 9.5mA @ 24VDC, 13.5mA @ 115VAC, 11.0mA @ 237VAC

Operating Temperature: -40oF to +180oF

Surge Protection: Zener Diode/ MOV

Output Relays (2): 1Amp 30VDC

Loop Input: Transformer Isolation, Lighting and Transient Protection (1)

Loop Inductance Range: 20 - 2000 uH Q-Factor of 5 or Higher

Tuning: Automatic on Reset or Power Up

Tracking: Automatic for Environmental Changes

Size: 3.25" x 2.56" x 3.65" (83mm x 40mm x 90mm)

Housing: Extruded Anodized Aluminum

Connector: 86C911 11 Pin Male